江苏省扬州市宝应县柳堡工业园区
客服qq: 1097458444 1753928444
电 话:0514-88773006
传 真:0514-88771096
e-mail:
变频抗干扰介质损耗测试仪检验报告-凯发k8555
变频抗干扰介质损耗测试仪检验报告
仪器精度: 1%
检验数据:
电容 |
介损 |
10kv |
|||
标准值 |
测量值 |
标准值 |
测量值 |
|
|
49.94pf |
49.94pf |
0.001% |
0.001% |
|
|
500.0pf |
500.01pf |
0.011% |
0.010% |
|
|
5.000nf |
5.001nf |
0.072% |
0.072% |
|
|
50.00nf |
50.01nf |
0.092% |
0.093% |
|
|
电容 |
介损 |
1kv |
|||
标准值 |
测量值 |
标准值 |
测量值 |
|
|
98.933pf |
98.93pf |
0 |
0 |
|
|
98.933pf |
98.93pf |
0.0101% |
0.011% |
|
|
98.933pf |
98.93pf |
0.0498% |
0.051% |
|
|
98.933pf |
98.93pf |
0.103% |
0.105% |
|
|
98.917pf |
98.92pf |
0.502% |
0.501% |
|
|
98.902pf |
98.90pf |
1.000% |
1.002% |
|
|
98.567pf |
98.57pf |
5.020% |
4.999% |
|
|
97.753pf |
97.75pf |
9.989% |
9.990% |
|
|
电容 |
介损 |
2kv |
|||
标准值 |
测量值 |
标准值 |
测量值 |
|
|
98.933pf |
98.94pf |
0 |
0 |
|
|
98.933pf |
98.93pf |
0.0101% |
0.012% |
|
|
98.933pf |
98.95pf |
0.0498% |
0.051% |
|
|
98.933pf |
98.96pf |
0.103% |
0.102% |
|
|
98.917pf |
98.93pf |
0.502% |
0.499% |
|
|
98.902pf |
98.91pf |
1.000% |
1.001% |
|
|
98.567pf |
98.52pf |
5.020% |
4.999% |
|
|
97.753pf |
97.76pf |
9.989% |
9.985% |
|
|
电容 |
介损 |
5kv |
|||
标准值 |
测量值 |
标准值 |
测量值 |
|
|
98.933pf |
98.93pf |
0 |
0 |
|
|
98.933pf |
98.93pf |
0.0101% |
0.010% |
|
|
98.933pf |
98.94pf |
0.0498% |
0.051% |
|
|
98.933pf |
98.93pf |
0.103% |
0.102% |
|
|
98.917pf |
98.92pf |
0.502% |
0.505% |
|
|
98.902pf |
98.91pf |
1.000% |
1.001% |
|
|
98.567pf |
98.57pf |
5.020% |
5.021% |
|
|
97.753pf |
97.73pf |
9.989% |
9.990% |
|
|
电容 |
介损 |
7.5kv |
|||
标准值 |
测量值 |
标准值 |
测量值 |
|
|
98.933pf |
98.93pf |
0 |
0 |
|
|
98.933pf |
98.94pf |
0.0101% |
0.0102% |
|
|
98.933pf |
98.93pf |
0.0498% |
0.0501% |
|
|
98.933pf |
98.93pf |
0.103% |
0.104% |
|
|
98.917pf |
98.90pf |
0.502% |
0.498% |
|
|
98.902pf |
98.91pf |
1.000% |
1.000% |
|
|
98.567pf |
98.55pf |
5.020% |
4.999% |
|
|
97.753pf |
97.75pf |
9.989% |
9.987% |
|
|
电容 |
介损 |
10kv |
|||
标准值 |
测量值 |
标准值 |
测量值 |
|
|
98.933pf |
98.93pf |
0 |
0 |
|
|
98.933pf |
98.93pf |
0.0101% |
0.010% |
|
|
98.933pf |
98.93pf |
0.0498% |
0.050% |
|
|
98.933pf |
98.93pf |
0.103% |
0.102% |
|
|
98.917pf |
98.92pf |
0.502% |
0.500% |
|
|
98.902pf |
98.91pf |
1.000% |
1.003% |
|
|
98.567pf |
98.57pf |
5.020% |
5.019% |
|
|
97.753pf |
97.75pf |
9.989% |
9.987% |
|
|
检验结论:
本台仪器数据符合精度要求. 合格